UPS Battery Systems
Needs and Product Solutions
Reducing risk of network outage

Data Centers, Manufacturing Facilities, Healthcare institutions and other mission critical operations invest in UPS battery systems to ensure absolutely reliable power. However, these UPS battery systems are dependent on batteries to store energy and batteries by their very nature can be unreliable.
Solution
Battery management programs and systems that utilize UPS battery monitoring, like Midtronics CELLGUARD Battery Monitoring System and CELLTRON Battery Analyzers increase system reliability by keeping close watch on batteries.
IMPROVED UPS BATTERY MAINTENANCE EFFICIENCY

UPS battery maintenance is key to continued reliable operation, but this maintenance is periodic, leaving risk between checks and can also be expensive.
Solution
Midtronics offers UPS battery monitors, battery analyzers, systems and programs to reduce risk and time and capital spent on maintenance.
LOWERING POWER CONSUMPTION AND REDUCING COST

Properly maintained and operating UPS and battery systems last longer and consume less energy to charge.
Solution
Midtronics CELLGUARD Battery Monitoring Systems and CELLTRON Analyzers help address inefficient battery systems through the use of UPS battery monitors and battery analyzers.
Midtronics Product Solutions
CELLTRON MAX |
|
|
|
Key Application:
Telecom Central Office
Telecom OSP (Outside Plant)
Wireless MTSO (Flooded
and VRLA) / Wireless Base Stations |
|
Test Range: |
100 - 19,990 mhos |
|
Test Data Storage: |
Unlimited internal memory USB to flash drive or PC |
|
Test Data Transfer To PC: |
USB, two way communication with SW for setup & download |
|
Capacity Test Manager: |
Voltage and time capture |
|
Battery Reference Developer |
|
AC Ripple Supression
Technology |
|
Full Multimedia / Scope
Function |
|
Field Upgradable Software |
|
Generator/Fleet Vehicle
Battery Testing Capability |
|
Integrated Temperature
Measurement |
|
Variation Based Analysis of
Conductance vs. Baseline |
|
|
CELLTRON ULTRA |
|
|
|
Key Application:
Telecom Central Office
Telecom OSP (Outside Plant)
Wireless MTSO (Flooded
and VRLA) / Wireless Base Stations |
|
Test Range: |
100 - 19,990 mhos |
|
Test Data Storage: |
Removable SD memory card stores 500 strings / locations of 480 tests |
|
Test Data Transfer To PC: |
InfraRed data transfer SD memory card |
|
Battery Reference Developer |
|
AC Ripple Supression
Technology |
|
Full Multimedia / Scope
Function |
|
Field Upgradable Software |
|
|
CELLTRON ADVANCED |
|
|
|
Key Application:
Single Phase UPS Systems |
|
Test Range: |
100 - 19,990 mhos |
|
Test Data Storage: |
16 strings / memory locations of 480 test results |
|
Test Data Transfer To PC: |
InfraRed data transfer |
|
Midtronics Service Center
upgradable software |
|
|
CELLTRON ESSENTIAL |
|
|
|
Key Application:
Single Phase UPS Systems |
|
Test Range: |
100 - 19,990 mhos |
|
Test Data Storage: |
1 string memory location of 480 test results |
|
Test Data Transfer To PC: |
Not available, IR printing only |
|
Midtronics Service Center
upgradable software |
|
|
SCP 6/12 |
|
|
|
Key Application:
Small Systems (Emegency lighting, alarm panels)
- 6 and 12 volt nominal batteries from 1.2 to approximately 55 ampere hours in capacity
- Voltmeter: +6.0 to +14.0 VDC
- Conductance: 20 to 1200 siemens
- Operating Temperature: -18 to 50ºC (0 to 120ºF)
|
|
|
|
|
CELLGUARD SYSTEM |
|
|
|
Key Application:
Telecom Central Office
Telecom OSP (Outside Plant)
Wireless MTSO (Flooded
and VRLA) / Wireless Base Stations
Communications Interfaces
Ethernet 10 Mbps
RS232 or serial USB ( @ 57.6 kbps)
802.15.4 compliant RF transport
@ 2.4 GHz Radio Band
Temperature
Operating Temperature
( 0° C to +65° C)
Storage Temperature
( -10° C to +80° C)
Power Requirements
Base Coordinator Unit Power
Powered by 9 V DC wall plug adaptor
or powered from VTC (optional)
VTC Unit Power
Powered from the battery (< 60 mA)
2 V Sensor Power
Powered from the battery
under surveillance
12 V Sensor Power
Powered from the battery
under surveillance.
Conductance Measurement Range
100 to 15,000 Siemens (cell mhos)
Strap Resistance Measurement
2 micro Ohms minimum
Test Current
2V & 12V Sensors
Test current is approximately 5 Amps RMS |
|
Voltage Measuring Characteristics
Sensor
Voltage range: 1.4 V to 2.5 V per cell
Resolution: +/- 20 mV
Sensor Negative Battery
Post Temperature Reading
Temperature Range
( 0° C to +65° C)
Measurement Accuracy
(+/- 2° C)
String Voltage Measurement
Input Range
42 to 600 Volts DC
AC Ripple
Peak AC Ripple Detection
String Current Measurement
Float State 300 milli-Amps to 10 Amps
Charge State 10 to 200 Amps
Discharge State 10 to 200 Amps
Physical Dimensions
Base Coordinator Unit
5.08 in x 5.25 in x 2.25 in
12.9 cm x 13.3 cm x 5.7 cm
VTC String Monitor
5.08 in x 5.25 in x 2.25 in
12.9 cm x 13.3 cm x 5.7 cm
2 V & 12 V Sensor
4.45 in x 3.15 in x 1.5 in
11.3 cm x 8 cm x 3.8 cm |
|
|
Data Management
CELLTRAQ
|
|
|
|
Key Application:
Telecom Central Office
Telecom OSP (Outside Plant)
Wireless MTSO (Flooded
and VRLA) / Wireless Base Stations
- Windows Operating System
- Tomcat Web Server
Tomcat: 2G RAM or above (4G is recommended)
CPU: 2.6G or above
- SQL Server 2000/2005 Database
Database: 4G RAM or above (8G is recommended)
CPU: 2.6G or above
Installation CD provides, in addition to the
Server Application, Database, and SMTP Tester
Interface:
- Installation Manual
- JDBC-SQL Server Driver
- Java Development Kit (JDK)
- Tomcat
|
|
|
BATTERYNET
|
|
|
|
Key Application:
Telecom Central Office
Telecom OSP (Outside Plant)
Wireless MTSO (Flooded and VRLA) / Wireless Base Stations
- Industry’s proven source for effective battery data management and report automation
- More consistent, effective and efficient battery maintenance
- Professional level reports
- Proven efficiency in providing early warning on battery degradation
- Establishes battery inventory stocking levels based on unit density and change
|
|
|
FACILITYWARE
|
|
|
|
Key Application:
Telecom Central Office
Telecom OSP (Outside Plant)
Wireless MTSO (Flooded
and VRLA) / Wireless Base Stations
- Centralized record keeping and maintenance data on everything (outside of batteries) that is key to a well-run operation.
- User configurable database and reporting tools
- Collects and reports on critical information regarding generators, switchgear, power boards, HVAC and CRAC units, and much more
- Reliability in scheduling the next maintenance or responding to an audit request
|
|
|
|