CELLTRON ADVANCED

Communicating Power

The CELLTRON ADVANCED  is a professional level portable battery analyzer used for stationary battery management. Research proven technology and field-tested design make it a must for critical power maintenance in mobile telecom switching offices, cellular/wireless base stations, and telecom network outside plant installations. With the growing criticality of broadband systems for data and voice transmission, a testing program utilizing the CELLTRON ADVANCED increases maintenance efficiency and maximizes battery asset utilization all while ensuring power system reliability. Compatible with the PowerSure database, the CELLTRON ADVANCED measures individual cell and overall string health and voltage. Conductance technology allows for quick, simple, safe and accurate testing. Passive test method minimizes technician and system risk while reducing testing time to less than 10 seconds per cell. The CELLTRON ADVANCED provides consistent and repeatable on-line testing without battery discharge and tests both battery cell and intercell strap integrity. The CELLTRON ADVANCED helps prioritize battery replacements for more cost-effective system management by providing advanced warning of potential battery failures. Ensure that your system will never experience down time without battery backup power with the CELLTRON ADVANCED for UPS, telecommunications and broadband applications.

  • High ampere-hour (up to 6000 AH) battery test capability
  • 16 internal memory registers capable of storing 480 consecutive test results and string statistics
  • Quick re-test function to correct erroneous entries
  • Tests 2-volt through 16-volt batteries on-line or off-line
  • Voltage measurement to 3 decimal places
  • 16 volt testing capability
  • Tests multiple intercell connectors and 8 posts
  • Enhanced backlit display and screen resolution
  • Voltage logging only option
  • No external power source needed
  • Portable IR wireless printing and data transfer to PC laptop
  • User definable battery reference number storage and fault threshold
Midtronics battery testers and analyzers make compliance with the new NERC standard PRC-005-2 quick and easy.
 

CELLTRON ADVANCED (CTA-2000)

Model Number: CTA-2000

Warranty: Midtronics standard one-year warranty

Applications:

  • Telecommunications (Central office and outside plant)
  • Power utility (generation, transmission and distribution) switching and station batteries
  • Uninterruptible Power Supply maintenance
  • Other professional stationary battery service

Conductance Range: 100-19,900 Mhos/Siemens

Battery Capacity Range: 10 Ah to 4000 Ah approx.

Power Requirements: One 9 volt high capacity/heavy duty lithium battery required (included), powered by battery under test for some test operations

Voltage Range: 1.0-15.0 Volts DC

Display: Enhanced backlit graphical LCD with resolution control for varying light environments

Operating Temperature: 0 to +40 degree C, 95% relative humidity, non-condensing

Interface Operations:

  • Dura probes
  • Dura clamps
  • Standard clamps
  • Mini-probes
  • End-of-Train device cable
  • Others, including customs available

Housing Material: Acid and impact resistant ABS plastic

Product Dimensions: L9" X 4" X 2.5" (230 mm X 102 mm X 65 mm)

Product Weight: 1 lb / 427 grams

Over Voltage Protection: Fused protection to 60-volts DC

Test Data Storage: 16 strings of 480 tests

Temperature Compensation: Automatic adjustments on temp input

Calibration: Auto calibration prior to every test, no future calibration required

 

C041
CTA Duraprobe Extender KIT

Click to Enlarge

A087
Printer

A087 Printer

Click to Enlarge

C016
Celltron Rechargeable Battery Pack

Click to Enlarge

C033
Optic Lamp Kit

Click to Enlarge

C041
CTA Duraprobe Extender KIT

Click to Enlarge

C046
CTA Miniprobe

Click to Enlarge

C049
IR Receiver

Click to Enlarge

C051
Rechargeable Battery

Click to Enlarge

C052
CTA WYE Cable

Click to Enlarge

C056
MicroCelltron Amp Cable

Click to Enlarge

C057
MicroCelltron Case

Click to Enlarge

C058
Temperature Sensor

Click to Enlarge

C059
Probe Contacts KIT

Click to Enlarge

C069
Duraprobe Replacement KIT

Click to Enlarge

C075
Duraprobe Extnders

Click to Enlarge

C087
CTA Duraprobe Cable Assembly

Click to Enlarge

C088
CTA Duraclamp Cable Asembly

Click to Enlarge

C092
CTA Duraclamp

Click to Enlarge

C091
Battery Charger

Click to Enlarge

C097
Fuses

Click to Enlarge

KBC-426
In Cabinet Kelvin Cable

Click to Enlarge

KTC-400
Incabinet CTM Cable

Click to Enlarge

KTC
CTU Cable InCABINET

Click to Enlarge

PDF40
Digital Amp Clamp Meter

PDF40 Digital Amp Clamp Meter

Click to Enlarge

CELLTRON ADVANCE

Instruction Manual

Choose Region

CELLTRON ADVANCE

Brochures

Choose Region

Extended Warranty

Brochures

Choose Region

 

Customer Service

sppservices@midtronics.com

Call Toll Free

1.888.776.1995

Corporate Office

7000 Monroe Street
Willowbrook, IL 60527

 

European Office

Midtronics b.v.
P.O. Box 287, 3990 GB Houten 
Hoofdveste 6-8, 3992 DG Houten 
The Netherlands

Phone: +31 306 868 150

 

China Office

Room 16E-1, Noble Center
No. 1006, 3rd Fuzhong Road
Shenzhen, China 518026

Close

Services & Support
Subject:
Select the product(s) that needs service or support:
CELLTRON MAX CELLGUARD Data Management
CELLTRON ULTRA CELLGUARD Battery Monitoring
CELLTRON ADVANCED Accessories
CELLTRON ESSENTIAL Not Listed
CELLTRON SCP-100 (Please identify in the message)
Message:
First Name: Last Name: Company:
Address:
City: State/Province/Region: Postal Code
Country: Phone Number Email Address:
Preferred method of contact: Phone E-mail
Addressing all fields is required in order for your request to be sent.